Fabrication of an amperometric Sarcosine (cas 107-97-1) biosensor based on Sarcosine (cas 107-97-1) oxidase/chitosan/CuNPs/c-MWCNT/Au electrode for detection of prostate cancer
-
Add time:08/22/2019 Source:sciencedirect.com
An amperometric Sarcosine (cas 107-97-1) biosensor was fabricated based on covalent immobilization of sarcosine oxidase (SarOx) onto the nanocomposite of carboxylated multi-walled carbon nanotubes (cMWCNT)/chitosan (CHIT) and copper nanoparticles (CuNPs), electrodeposited on gold (Au) electrode. The SarOx/CHIT/CuNPs/c-MWCNT/Au electrode was characterized by scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The enzyme electrode exhibited optimum current within 2 s at a potential of 0.2 V against Ag/AgCl, pH 7.0 and 35 °C. A linear relationship was obtained between sarcosine concentration in the range, 0.1–100 μM and current (mA) under optimum conditions. The biosensor exhibited a high sensitivity of 277.5 μA/μM/cm2, a low detection limit of 0.1 pM and excellent storage stability (180 days). The analytical recoveries of added sarcosine in sera at 0.5 μM and at 1.0 μM concentration were 95.5% and 97.30 respectively. The precision i.e. within and between-batch coefficients of variation (CVs) were 1.08% and 1.70% respectively. There was a good correlation (R2 = 0.99) between the level of sarcosine in sera as measured by the standard immuno kit method and the present biosensor. The biosensor measured sarcosine level in sera of prostate cancer patients, which was significantly higher than those of apparently healthy persons (p value <0.01).
We also recommend Trading Suppliers and Manufacturers of Sarcosine (cas 107-97-1). Pls Click Website Link as below: cas 107-97-1 suppliers
Prev:Xylose as preferred substrate for Sarcosine (cas 107-97-1) production by recombinant Corynebacterium glutamicum
Next:In vitro selection of DNA aptamers for the development of fluorescent aptasensor for Sarcosine (cas 107-97-1) detection) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- ArticleSarcosine (cas 107-97-1) Is Uniquely Modulated by Aging and Dietary Restriction in Rodents and Humans08/27/2019
- Construction and application of amperometric Sarcosine (cas 107-97-1) biosensor based on SOxNPs/AuE for determination of prostate cancer08/26/2019
- Platinum-loaded mesoporous nickel phosphonate and its electrochemical application for Sarcosine (cas 107-97-1) detection08/25/2019
- A highly sensitive DNA aptamer-based fluorescence assay for Sarcosine (cas 107-97-1) detection down to picomolar levels08/24/2019
- In vitro selection of DNA aptamers for the development of fluorescent aptasensor for Sarcosine (cas 107-97-1) detection08/23/2019
- Xylose as preferred substrate for Sarcosine (cas 107-97-1) production by recombinant Corynebacterium glutamicum08/21/2019
- A novel and sensitive Sarcosine (cas 107-97-1) biosensor based on organic electrochemical transistor08/20/2019
- Amperometric Sarcosine (cas 107-97-1) biosensor based on hollow magnetic Pt–Fe3O4@C nanospheres08/19/2019
- Towards Sarcosine (cas 107-97-1) determination in urine for prostatic carcinoma detection08/18/2019
-
Health and Chemical more >